Copeland QR12M1-TFD-501 Details

Delving into the detailed technical specifications of the Copeland QR12M1-TFD-501 compressor, reveals a robust design intended for demanding refrigeration systems. The unit boasts a displacement of approximately 12.5 cubic centimeters, designed to operate with refrigerant R-124yf. Its operating electrical power is 230 volts, with a hertz of 60Hz, and it usually draws a peak current of roughly 7.3 Amps, and a full-load current approximately 4.1 Amps. Furthermore, its engineered capacity falls within a spectrum dependent on operating conditions, with a maximum discharge temperature stipulated at 105°C. Examine the full documentation for precise setup and maintenance instructions. A unique feature incorporates its integrated lubricant management module ensuring optimal performance and lifespan throughout its working period.

Copeland QR12M1-TFD-501 Technical Data

Analysis of the Emerson QR12M1-TFD-501 cooling unit's technical data reveals notable insights for application optimization. Specifically, tests conducted at varying ambient temperatures, ranging from 50°F to 131°F, demonstrate a reliable capacity of approximately 12.1 RT with a measured Coefficient of Efficiency fluctuating between 3.2 and 3.8. Furthermore, electrical consumption requirements averaged 42.3 electric power under standard Copeland QR12M1-TFD-501 assessment conditions, showing minor variations depending on operating parameters. Preliminary data points to a low oil return rate, generally below 2%, which contributes to extended component durability. A detailed assessment outlining these findings and suggestions for peak employment is accessible upon demand.

Summary of the QR12M1-TFD-501 Copeland Compressor

The QR12M1-TFD-501 Brand unit represents a significant advancement in refrigeration technology, particularly suited for commercial air conditioning and refrigeration applications. Characterized by its scroll design, this version delivers remarkable efficiency and reliability, typically found in systems requiring a cooling volume around 12,000 BTU. It's designed for demanding environments, boasting durable construction and refined performance, making it a preferred choice for installers and repair professionals alike. Considerations for its placement include proper gas charging and adequate electrical supply to ensure maximum operational operation.

Troubleshooting Copeland QR12M1-TFD-501

Addressing difficulties with a Copeland QR12M1-TFD-501 compressor demands a structured approach, especially considering its common application in industrial refrigeration systems. A frequent problem involves significant vibration, often linked to damaged internal parts like the connecting rods or crank assembly. Begin by verifying the power supply; an unstable input can trigger erratic compressor behavior. Inspect the relay for proper closure, as a failing contactor can result in intermittent refrigeration output and overheating. Furthermore, a thorough assessment of the chiller lines, including ensuring for blockages and proper amount, is absolutely necessary. Finally, don’t overlook the possibility of a damaged fluid pump, which drastically decreases lubrication and can rapidly lead to severe harm. It is recommended to consult the published Copeland manual for specific troubleshooting procedures and safety guidelines.

Locating A QR12M1-TFD-501 Substitute Choices

If your the QR12M1-TFD-501 compressor is experiencing problems or simply reaching the conclusion of its service period, securing a appropriate alternative is crucial. While identical replacements can be more challenging to pinpoint, several choices are available. Consider examining alternative cooling models from vendors like Bitzer – though compatibility needs to be thoroughly checked with a licensed refrigeration expert. Sometimes, a moderately varying design with comparable capabilities can work efficiently after some minor modifications. Remember to always consult the manufacturer's specifications for critical parameters like voltage and coolant kind.

Guidance on the QR12M1-TFD-501 Compressor Application

Navigating the complexities of air conditioning systems often demands precise understanding of component compatibility. The QR12M1-TFD-501 Copeland compressor presents a unique collection of operational characteristics, and this document aims to clarify its appropriate application. Specifically, this resource details its recommended performance parameters when employed within industrial chilling applications, frequently encountered in food processing plants and large retail facilities. Improper fitting or exceeding the specified running conditions can lead to premature breakdown, so meticulous following to the outlined directives is paramount. A detailed evaluation of refrigerant types, power requirements, and environmental temperature constraints is included to facilitate informed decision-making during the system planning phase.